MEDICAL PENDANTS

OPTIMUM SERIES

OPTMUM SERE

FOR:

EMERGENCY ROOM

OPERATING ROOM

DELIVERY ROOM

 

CATALOGUE

*Increased Hygiene and sterility

*Ease to use

The many advantages in the field of safety and hygiene are;

*No more trailing leads, cables or hoses,

*Fully encapsulated system,incorporating modular service boxes, which makes maintenance and general use easier.

*Single or two piece arm assemblies, motorised, or static, equipment can now be located at the point of use with the greatest of ease.

*Fully equipped to suit the application, with high and low voltage supplies, medical gas outlet points,communication points and various miscellaneous items.

*Heavy Duty Structures

*Easy Cleaning of All Parts for Hygiene purposes

*Equipment Shelf with optional pressure Gauges for Each Medical Gas

*Electrical and Medical Gas Outlets in separate compartments

*Side Rails for IV Stands and Equipment

STANDARDS

Schönn pendants are manufactured in compliance to HTM2015, HTM2022, HTM02-01, DIN 13260, DIN 49440, DIN 57750, DIN 42801, EN 737 and the units are CE marked.

 

 

ARM CEILING RIGID PENDANT- SACP-90

 

PRACTICAL CONSIDERATIONS

The standard recommended height of the lower face of  pendants is 1,1-1,3 meter, however,this does not take into account the differing heights of theatre  personnel,or conditions needed for particular operations.

The pendant allows the unit  to be lifted above working height when the unit is not required,but also allows the height to be adjusted so suit particular circumstances. (Optional feature)

The pendant should be located near the head of the operating table.

However, note must be taken of any moving equipment in the theatre, such as operating theatre lamps etc. , to ensure that the location of the pendant  does not foul this equipment.

FINISH

The pendant is supplied in RAL 9002 Electrostatic Powder Coated finished.

INSTALLATION

The services are run to a first-fix unit in the ceiling. For medical gases, these services will  terminate in Non-Interchangeable Screw Thread connection (NIST) to BS 5682.The first-fix installation should be completed, fully tested and blanked until the second-fix installation is required for intallation.

The pendant is supplied as a second-fix item for installation during the finishing of the theatre and is normally supplied with all components installed and tested in the factory.

Gas service are via flexible connectors to EN 739 which are attached to the first NIST connectors  to BS 5682.

The pendants  are supplied with a bevelled fascia plate to provide a neat junction at the ceiling. All securing bolts must be adequate for the load of the pendant.Any  framework must also be designed for rigidity.Even small loads,such as those imposed by inserting gas probes can cause large deflections on a long  pendant. Any supporting framework should be designed for maximum rigidity to avoid these deflections.

 

MAINTENANCE

Maintenance is important for this pendant to ensure that the flexible connectors have not become worn, Generally,these connectors should be replaced regularly.

Maintenance of components should be in accordance with the manufacturers instructions. It is recommended that the maintenance requirements for the components be combined into one programme of maintenance for the pendant and incorporated into the planned maintenance programme for the hospital.

SAFETY

Particular care should be taken when installing pendants with several gases to ensure that the pipeline to each gas terminal outlet is connected to the correct gas supply system.Checks should be made using gas flow and gas identity tests to ensure that the connections are correct.

Care should be taken ensure that electrical earth connections are not disturbed and to ensure that the pendant itself is correctly electrically bonded to the gas and electricity supply to avoid hazard to patients and theatre personnel.

 

MULTI MOVEMENT ELECTRIC Single- Twin ARM PENDANT- SMTP-90 / SMSP-90

PRACTICAL CONSIDERATIONS

Electric Arm Pendants can be classified as Single Electric Arm Pendant and  Twin Electric Arm Pendant.

As its name implies Single Electric Arm Pendant has a Single Arm which has capability of 340 rotation around its vertical axis and a vertical movement of max 690 mm provided by an electric motor.Twin Electric Arm Pendant has two arms.

The length of the arms are 800 mm and the arm moves horizontally and rotates 340° on its vertical axis.The 1000 mm Electric Arm moves vertically max.  690 mm by an electric motor.

FINISH

The pendant is supplied in RAL 9002 Electrostatic Powder Coated finished.

INSTALLATION

The supply services are run to a first-fix unit in  the ceiling. For medical gases, these services will terminate in Non-Interchangeable Serew Thread connections (NIST) to BS 5682.The first-fix installation should be completed, fully tested  and blanked until the second-fix installation is required. The pendant is supplied as a second-fix item for installation during the finishing of the  theatre and is normally supplied with all components installed and tested in the factory.

Gas service are via flexible connectors to EN 739 which are attached to the first-fix NIST connectors to BS 5682.

The pendants is supplied with a bevelled fascia  plate to provide a neat junction at the ceiling.

All securing bolts must be adequate for the load  of the pendant and the structural ceiling construction. Any supporting  frameswork must also be designed for rigidity.

Even small loads,such as those imposed by inserting  gas probes can cause large deflections on a long pendant.Any supporting framework should designed  for maximum rigidity to avoid these deflections.

MAINTENANCE

Maintenance is important for this type of pendant to ensure that the flexible connectors have not become worn. Generally, these connectors should be replaced  regularly. Maintenance of components should be in accordance with the manufacturer instructions. It is recommended that the maintenance requirements for the components be combined into one programme of maintenance for the pendant and incorporated into the planned maintenance programme for the  hospital.

STANDARDS

Schönn pendants are manufactured in compliance to HTM 2015 & HTM 2022, HTM02-01, DIN 13260, DIN 49449, DIN 57750, DIN 42801 EN 737 and they are CE marked.

SAFETY

Particular care should be taken when installing pendants with several gases to ensure that the pipeline to each gas terminal outlet is connected to the correct gas supply system. Checks should be made using gas flow and gas identity  tests to ensure that the connections are correct. Care should be taken ensure that electrical earth connections are not disturbed and to ensure that the  pendant it self is correctly electrically bonded to the gas and electricity supply  to avoid hazard do patients and theatre personnel.

 

HORIZANTAL Single- Twin ARM PENDANT SHSP-90 / SHTP-90

 

PRACTICAL CONSIDERATIONS

Horizontal Arm Pendants can be classified as Single Horizontal Arm Pendant and Twin Horizontal Arm Pendant.

 As its name implies, Single Horizontal Arm Pendant has a Single Arm (1000 mm long)which has a capability of 340° rotation around its vertical axis. Twin Horizontal Arm Pendant has two arms 600 mm and 800 mm long respectively and capable of reaching further distances of equipment in the area installed.

Lenght of  Arms used in Pendants are standard and 1000 mm for Single  Horizontal Arm Pendant and 600 and 800 mm for Twin Horizontal Arm Pendant. Optionally, other sizes can be manufactured upon customer reguest.

FINISH

The pendant is supplied in RAL 9002 Electrostatic Powder Coated finished.

INSTALLATION

The supply services are run to a first-fix unit in  the ceiling. For medical gases, these services will terminate in Non-Interchangeable Serew Thread connections (NIST) to BS 5682.The first-fix installation should be completed, fully tested  and blanked until the second-fix installation is required. The pendant is supplied as a second-fix item for installation during the finishing of the  theatre and is normally supplied with all components installed and tested in the factory.

Gas service are via flexible connectors to EN 739 which are attached to the first-fix NIST connectors to BS 5682.

The pendants is supplied with a bevelled fascia  plate to provide a neat junction at the ceiling.

All securing bolts must be adequate for the load  of the pendant and the structural ceiling construction. Any supporting  frameswork must also be designed for rigidity.

Even small loads, such as those imposed by inserting  gas probes can cause large deflections on a long pendant.Any supporting framework should designed  for maximum rigidity to avoid these deflections.

MAINTENANCE

Maintenance is important for this type of pendant to ensure that the flexible connectors have not become worn. Generally, these connectors should be replaced  regularly. Maintenance of components should be in accordance with the manufacturer instructions. It is recommended that the maintenance requirements for the components be combined into one programme of maintenance for the pendant and incorporated into the planned maintenance programme for the  hospital.

STANDARDS

Schönn pendants are manufactured in compliance to HTM 2015 & HTM 2022, HTM02-01, DIN 13260, DIN 49449, DIN 57750, DIN 42801 EN 737 and they are CE marked.

SAFETY

Particular care should be taken when installing pendants with several gases to ensure that the pipeline to each gas terminal outlet is connected to the correct gas supply system. Checks should be made using gas flow and gas identity  tests to ensure that the connections are correct. Care should be taken ensure that electrical earth connections are not disturbed and to ensure that the  pendant it self is correctly electrically bonded to the gas and electricity supply  to avoid hazard do patients and theatre personnel.

 


DOUBLE ARM PENDANT SDAP-90

 

DESCRIPTION:

 To provide the ideal arrangement for all necessary services and equipment connection facilities required in an ICU or CCU for all clinical purposes. 

 The Double Arm ICU Pendant is manufactured from extruded aluminium profile and coated by electrostatic powder paint.

 The Double Arm Pendant has a ‘Wet Side’ and a ’Dry Side’ equipment  console.

 Wet Side Equipment Console will have drip hook, infusion stands,  equiment rail as well as gas and electric services.

 Dry Side equipment console will have shelves for equipment, Drawer and  gas and electric services.

 

MANY ADVANTAGES IN THE FIELD OF SAFETY AND HYGIENE

 No more cables and hoses on the floor which cause on obstruction to free movement, because all cables and hoses are integrated into the  pendant system.

 All necessary pieces of equipment are set on individually adjustable trays, or attached to rails or poles.

 This results in an unobstructed and working  space and leaves floor space free for the use of medical (or other) equipment.

 Conduits and fittings are built into the unit so that they are not visible and, therefore,giving and surface that is easy to clean. The ceiling  suspension system is maintenance free.

 Equipment is connected by means for short connecting hoses or cables for medical gases  and electricity.

 Single or twin support arms can be easily extended using modules to suit the requirements of a specific application.

 The arms rotate on high quality bearings, so that the technical consoles can be very smoothly and quickly moved into any position.

 The support arms are solidly built to enable heavy devices (monitors pumps etc.) to be carried on the consoles.

 Double Arm O.R Pendant has advantage of  are Arm moving vertically by electric motor  supplying a comprehensive facility for larger  Operating Theaters.

 

MATERIALS USED

 Support arms set on high-quality, maintenance-free bearings with low frictional resistance

 Rotating arms are of high tensile steel profiles.

 Covers are of painted steel sheet or painted plastic

 Technical consoles are made of electrostatic powder coated aluminium and/or Steel material.

 Plastic components are of highly flame-resistant material

 Colour: RAL 9002 (grey-white) and RAL 9016 (white)